Pilot Plants & Laboratory Equipment
Send Message +96892980524

Category: Drilling Laboratory

Drilling Laboratory

Showing 1–16 of 26 results

  • Friction Measuring Device in Pipes

    Equipment’s Fluid Friction Apparatus enables us to study flow, flow measurement techniques, and losses in a wide variety of pipes and fittings. The equipment has three water circuits with instruments, pipes, and pipe system components. The flow measurement instruments show the common methods of measuring water flow and measure pressure losses across instruments or components. They also give applications of the steady flow energy equation (Bernoulli’s equation).

    Request for quote
    Read more
  • Saybolt Viscometer

    The Saybolt viscometer is a device that controls the heat of the fluid. Moreover, the viscosity is the time taken for the fluid to fill the container. These viscometers are most commonly used for fieldwork to measure the viscosity of oils, syrups, varnish, paints, and bitumen emulsions. The Saybolt viscometer can be found in different versions.

    Request for quote
    Read more
  • Ostwald’s Viscometer

    Ostwald viscometer, also known as U-tube viscometer or capillary viscometer is a device used to measure the viscosity of the liquid with a known density. The method of determining viscosity with this instrument consists of measuring the time for a known volume of the liquid (the volume contained between the marks A and B) to flow through the capillary under the influence of gravity. The instrument must first be calibrated with materials of known viscosity such as pure (deionized) water. Knowing the value of the viscosity of one liquid, one can calculate the viscosity of another liquid.

    Request for quote
    Read more
  • Aniline–Point Measuring Device

    This device is designed and manufactured under GB Determination of Aniline Point in petroleum products of testing aniline point of dark petroleum products. This device is used in oil and grease laboratory, oil and gas laboratory, petrochemical laboratory, refineries, standard laboratories, and research laboratories. Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures.

    Request for quote
    Read more
  • Flash Point Measuring Device

    This device is used to determine the flashpoint value of petroleum products, which is the temperature point at which the sample vaporizes to another composition state in the air that can be ignited. At that moment, the flashpoint apparatus can determine and measure the vapor pressure change in which this occurs, also known as the lowest limit of flammability. Therefore, vapor concentration can be determined by temperature.  It is widely used in railway, aviation, electrical power, oil industries, and scientific research departments, etc.

    Request for quote
    Read more
  • Penetration of Bituminous and Lubricating Grease Materials Measuring Device

    This device is used to determine the penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt, and emulsified asphalt. It is also suitable to set solid particles, powder, colloid, and raw-food materials such as cheese, glycine, butter, cream, and leavening. It can be widely used in highway engineering and other industrial fields.

    Request for quote
    Read more
  • Softening Point of Asphalts and Tar Pitches Measuring Device

    This device is designed and made as per the national standard test method for softening point of asphalt. It makes it possible to determine the softening point of asphalt, tar, liquid asphalt, and other types of asphalt. It is the best choice of asphalt manufactures, highway and bridge construction companies, colleges and universities, and research and development departments. Additionally, it adopts microcomputer control technology, linear heating, and automatic stirring working mode, which makes it convenient, efficient, and reliable.

    Request for quote
    Read more
  • Smoke Point Measuring Device

    This device is capable of determining the smoke point of kerosene and aviation turbine fuels. This device burns fuel samples under controlled conditions for smoke point determinations of aviation turbine fuels and similar products. Moreover, it consists of a chimney, glass scale, curved glass window, candle socket, a candle with wick tube, and air vent.

    Request for quote
    Read more
  • Distillation Apparatus for Petroleum Fluids

    This apparatus is designed and made as per the standards test method for distillation characteristics of petroleum products and the ASTM standard test method for distillation of Petroleum products at atmospheric pressure. It is suitable to determine the distillation characteristics of gasoline, aviation gasoline, jet fuels, and a solvent having a special boiling point, naphtha, diesel oil, distillate fuels, and similar petroleum products.

    Request for quote
    Read more
  • Reid Vapor Pressure Measuring Device

    The REID vapor Pressure Measuring device is an automated Reid Vapor pressure instrument that measures the vapor pressure of gasoline, volatile crude oil, and other volatile petroleum products. The RVP test is used in various quality control and R&D applications. RVP tests measure the potential impact of gasoline on engine performance and help benchmark fuels for various emission regulatory compliance programs.

    Request for quote
    Read more
  • Pour Point Measuring Device

    Pour points expresses the lowest temperature of the sample which is kept in liquidity while cooled under certain standards. Pour point devices are generally used in labs that analyze oil produce (naphtha-biodiesel) while testing samples whether they are appropriate to the standards or not.

    Request for quote
    Read more
  • Cloud Point Measuring Device

    Cold flow properties, such as Cloud Point and Pour Point, indicate how petroleum products behave at low temperatures. The test specimen is cooled at a specified rate and measured periodically. The highest temperature at which a cloud is first detected at the bottom of the test jar is recorded as the cloud point. The lowest temperature at which movement of the specimen is detected is recorded as the pour point. This device is designed to provide a highly accurate cloud of temperatures of petroleum products during cooling.

    Request for quote
    Read more
  • Copper Corrosion Measuring Device

    The instrument is designed and made for the detection of copper corrosion from petroleum products by the copper strip tarnish test. It is suitable to determine the corrosiveness of gas, jet fuels, vehicle gasoline, natural gasoline, a hydrocarbon with Reid vapor Pressure, solvent oil, diesel oil, distillate oil, lubricating oil, and other petroleum products, to copper.

    Request for quote
    Read more
  • Mud Circulation Structure

    The device is used as a simulator of the mud circulation system. The drilling fluid circulating system is like a close loop electric circuit through which drilling fluid (i.e. mud) can travel from the surface to all the way downhole and back to its initial point (i.e. mud pit). The cuttings are then separated from the mud, which is then recycled.

    Request for quote
    Read more
  • Drilling Simulator Structure

    This apparatus is a real-time portable simulator drilling and equipment operations. Well control and crane training to the rig. Moreover, it replicates some physical process or operation to some level of fidelity. Reliable drilling simulator software can replicate the drilling process with a close level of fidelity. Different simulations with different parameters can identify the optimal results.

    Request for quote
    Read more
  • Rheometer

    VG meter measures the direct-indicating viscosity and the gel strength of the drilling fluid. It is a rotational cylinder and bob Rheometer. This instrument has 6 variable speeds. When the outer cylinder is full of drilling fluid, the inner cylinder rotates at a specific velocity. Hence, the torque which is exerted on the inner cylinder is measured accurately. Additionally, the viscosity is calculated based on the torque measurement.

    Request for quote
    Read more